Mail-In Calibration Service

Free shipping with 15 or more pipettes (both ways).

SHIPPING ADDRESS: 4310 Saratoga Parkway, Suite 100 

Plainfield, IN 46168
$40 Flat shipping fee for less than 15 pipettes.

  •  Disassemble the pipette.
  • Clean the shaft, piston and all internal parts with Acetone and hi-gloss metal polish.
  • Replace Teflon seal.
    Lubricate any necessary parts.
  • Reassemble the pipette.
    Make any necessary adjustments.
  • Clean exterior of the pipette.
  • Clean ejector.
  • Calibrate pipette to manufacturers’ specs.
    Place calibration sticker on every pipette.
  • One year warranty.
    24-72 hr. turn around time.

Mail-in Pipette
Calibration Service

Pipette calibration/reconditioning service per pipette

4 Levels of Services to choose from:

Basic Service

Pipette inspected, thoroughly cleaned, Gilson pipettes are cleaned using an ultra-sonic method, seal/o-ring replaced or lubricated, repairs performed and calibrated. Leak proof test performed. (Major parts are extra)

Smudge proof label affixed to the pipette, and Work Order Report generated with PASS/ FAIL Calibration Status.

From

$18

/Single Channel

Premium Service

Includes the Basic Level of cleaning, repair, calibration, and includes Calibration Certificate of 4 samples at low, high.

From

$28

/Single Channel

Platinum Service

Basic Level of Service performed and includes ISO 17025 Calibration Certificate: “As Left” 4samples at low, high. Calculations of %CV, % Accuracy and Mean is Auto-calculated.

Accounting for the uncertainty will be taken to mean that at a 95% confidence level the measurement result plus and minus the expanded uncertainty (k=2) shall be totally within the specification limits

Customized readings & specification limits are available at client’s requests also available for this option.

Call or e-mail for prices

Gold Service

Basic Level of Service performed and includes ISO 17025 Calibration Certificate: “As Found” data documented and a minimum of 4 samples at low, high. Calculations of %CV, % Accuracy and Mean is Auto-calculated.

Accounting for the uncertainty will be taken to mean that at a 95% confidence level the measurement result plus and minus the expanded uncertainty (k=2) shall be totally within the specification limits

Customized readings & specification limits are available at client’s requests also available for this option.

Call or e-mail for prices

To Get Started: